Products
Featured Products
Mc™ Micro Catheter consists of catheter hub, sheath tube, tube body, marker band and tip. The distal surface of the catheter has polyvinylpyrrolidone (PvP) hydrophilic coating with length of 25cm and thickness of about 5um.
The catheter was a single-lumen tube without lateral holes, The tube body is designed as a sandwich structure of "inner layer + middle layer + outer layer". The inner layer material is polytetrafluoroethylene PTfE), the middle strengthening layer is woven with 304 stainless steel wire, and the outer layer material is polyether block polyamide
(pebax). The distal site of the catheter contains a radiopaque platinum marker band and a tip of pebax.
The catheter was a single-lumen tube without lateral holes, The tube body is designed as a sandwich structure of "inner layer + middle layer + outer layer". The inner layer material is polytetrafluoroethylene PTfE), the middle strengthening layer is woven with 304 stainless steel wire, and the outer layer material is polyether block polyamide
(pebax). The distal site of the catheter contains a radiopaque platinum marker band and a tip of pebax.
Pulmo™ is a semi compliant rapid exchange pulmonary artery balloon dilation catheter with precise dilation size, controllable dilation degree,and good passabilityand push capability. Good rebound ability, can be repeatedlyexpanded multiple times, suitable forthe treatment of chronicthromboembolic pulmonaryhypertension.
Support Catheter consists of tip tube, tube body, catheter hub, and stress release tube and marker band. The distal surface of the catheter has polyvinylpyrrolidone (PvP) hydrophilic coating with length of 25cm and thickness of about 5um. The tube body is designed as a sandwich structure of "inner layer + middle layer + outer layer". The inner layer material is polytetrafluoroethylene (PTFE), the middle Strengthening layer is woven with 304 stainless steel wire, and the outer layer material is polyether block
polyamide (pebax) of varying hardness, The outer layer is divided into seven sections. The distal site of the catheter contains a radiopaque platinum marker band and a tip of pebax.
polyamide (pebax) of varying hardness, The outer layer is divided into seven sections. The distal site of the catheter contains a radiopaque platinum marker band and a tip of pebax.
Pulmo™ Spiral is a semi compliant rapid exchange pulmonary artery SPlRAL balloon dilation catheter with precise dilation size, controllable dilation degree, and good passability and push capability. Good rebound ability, can be repeatedlyexpanded multiple times, suitable for the treatment of chronic thromboembolic pulmonary hypertension.
MultiStage® Balloon Dilator is intended to be used to endoscopically dilate strictures located in the esophagus, pylorus, duodenum, colon and the airway tree, also available for use in ERCP biliary stone extraction and Dilatation Assisted Stone Extraction (DASE) procedures.
MultiStage® Balloon Dilator is intended to be used to endoscopically dilate strictures located in the esophagus, pylorus, duodenum, colon and the airway tree, also available for use in ERCP biliary stone extraction and Dilatation Assisted Stone Extraction (DASE) procedures.
Lifesupport™ Pulmonary Multichannel-MultiStage Balloon Dilator(PMM) system is intended to be used in urgent rescuing/supporting phenomena,especiallyforConvid19 endstage phenomena Ventilation,intubation, tracheal occlusion dilation,sputum aspiration, pulmonary oxygenation and auto biopsy can be performed simultaneously through the system.
PGC' pulmonary artery guide catheter is a non hydrated catheter consisting of a primary catheter and a secondary catheter, with the secondary catheter being smooth and unobstructedObstructivelyenterthe primary catheter and withdraw. Both primaryand secondary catheters consist of a tip, braided catheter, catheter seat, stress relieftube,and development marker, with only differences in catheter size. The distal surface ofthe catheter is coated with a PVP hydrophilic coating.
WPC™ pulmonary artery wedge pressure catheter consists of a balloon, inner tube, outer tube. three-way catheterseat, stress relieftube,and imagingring. The product packagingincludes a balloon protector, a two-way valve, a lml syringe, and a tearable sheath, Suitable for monitoring pulmonaryartery pressure or pulmonary artery wedge pressure.
Inflation Device is mainly used in PTCA surgery to pressurize the balloon dilation catheter, thereby dilating the balloon to achieve the purpose of dilating blood vessels or placing stents inside the blood vessels.
- Excellent twisting force and tensile strength, can efective reduce the damage to tissue.
- Hydrophilic coating design,with excellent performance.
- Easy for positioning,radiopaque tip with tungsten included, clearly seen under x-Ray.
- Integrated design oftip and core wire,impossible for falling off.
- Core-to-tip design provides 1:1 torque ratio.
- Hydrophilic coating design,with excellent performance.
- Easy for positioning,radiopaque tip with tungsten included, clearly seen under x-Ray.
- Integrated design oftip and core wire,impossible for falling off.
- Core-to-tip design provides 1:1 torque ratio.
MultiStage® Balloon Dilator is intended to be used to endoscopically dilate strictures located in the esophagus, pylorus, duodenum, colon and the airway tree, also available for use in ERCP biliary stone extraction and Dilatation Assisted Stone Extraction (DASE) procedures.